Water Technologies Water Softener Manual

July 3, 2024, 3:42 am

During these FILL and SOFTENING positions, you will have softened water available for use. Check drain line to be secure and that drain can receive the flow of water. Once the valve has completed the immediate regeneration, the valve will regenerate one more time at the preset. Do not elevate overflow line higher than 3" below bottom of overflow fitting. The display will either read backwash or fill and the remaining time in this step is counting down. Water flows through the control valve for normal operation of a water softener or filter. These units will deliver conditioned water for many years to come, when installed and operated properly. If water is available on the outlet side of the softener or filter, it is an indication of water bypassing the system (Fig. The brine tank is manufactured for the use of solar, pellets or rock salt. This fitting is an elbow on the side of the brine tank. EverGreen and AspenPro System Manuals.

Water Softener User Manual

Note the color of water coming from faucet. Any major appliance in your home can break or stop working at any time, including your water softener. M anual Regeneration: Sometimes there is a need to regenerate the system sooner than when the system calls for it, usually referred to as manual regeneration. Make provisions to bypass outside hydrant and cold hard water lines at this time. While the unit is rinsing, load the brine tank with water softener salt. Unplug transformer to keep the valve in the RINSE position. CAUTION: If water flows too rapidly, it could result in loss of media to the drain. NOTE: The system must be rinsed before returning the bypass valve to the normal position. 2 1 Nut, 1" quick connect 2 2 Split Ring 2 3 O-ring 215 2 4 Fitting 2 1" BRASS SWEAT 3/4" BRASS SWEAT Item No. If other displays do not appear, refer to manual. Attach a length of 1/2" I. tubing to fitting and run to drain.

Water Soft Water Softener Manual

1 Nut, 1" quick connect 2 2 Split ring 2 3 O-ring 215 2 4 Bypass rotor, 1" 2 5 Bypass cap 2 6 Bypass handle 2 7 Bypass rotor seal retainer 2 8 O-ring 135 2 9 O-ring 112 2 10 O-ring 214 2 16 Installation Fitting Assemblies: 1" PVC MALE NPT ELBOW Item No. Adjust time of regeneration hour with t and s buttons, AM/ PM toggles at 12. 2 Iron removal may vary depending on form of iron, pH and other local conditions. There is a small amount of "give" to properly connect the piping but the water softener is not designed to support the weight of the plumbing. Teflon® tape must be used on the threads of the 1" NPT inlet and and outlet, the brine line connection at the control valve, and on the threads for the drain line connection. Once this position is complete, you will notice a 240 Minute (4 hours) SOFTENING position. Please complete the steps as shown to the right. When that happens, it's time for a new water softener. There may be a period of heavy water usage because of guests or a heavy laundry day.

Water Tec Water Softener Manual

If the timer is not set correctly or it has failed, your softener could be running at the wrong time of day, or it might not be regenerating at all. Sometimes, the problem is embarrassingly simple, but you'd be surprised how often this happens. Information in this manual is different than what is needed for installation and servicing of a particular water treatment system.

Water Softener Service Manual

To remove a salt bridge, tap on it (not on the tank) with something hard and blunt. Plumbing must be done in accordance with all applicable local codes. Press and hold the regen button for 3 seconds until a regeneration begins. Or momentarily unplug power source from PC board B. check piston and spacer stack for obstruction C. replace piston(s) and spacer stack assy D. press next and regen or momentarily unplug PC board power E. check motor wiring F. replace or clean drive gear(s) G. reset drive bracket H. replace PC board I. reset PC board onto drive bracket 10 Troubleshooting Guide PROBLEM CAUSE A. motor not operating B. no power at outlet 6. The dealer should read this page and guide the installer regarding hardness, day override, and time of regeneration, before installation: For the installer, the following must be used: · Set Installer Settings... Hardness, Day Override (preset to 12 days), and Time of Regeneration (preset to 2:00 a. m. ) · Read Normal Operating Displays · Set Time of Day · Read Power Loss & Error Display For the homeowner, please read operating instructions and displays. We provide guides and manuals for our products. If backwash is shown in window, proceed to step 2b. Do not "tie" this tube into the drain line of the control valve. If desired, two regenerations within 24 hours are possible with a return to the preset program.

Water Flow 14 Replacement Parts: WATER METER & METER PLUG Item No. Our detailed manuals and installation videos make most installations a breeze. Do not open the bypass at this time, it will be filled in the backwash position. The water level is regulated by a float switch. Accessed by pressing set clock 2. If discolored let water run until clear. If it malfunctions, the tank may overfill and fail to empty. You'll have to empty it by hand, then clean it. Making internal changes to the system's operation will affect how it operates and may affect its functionality. If an extended power outage occurs, the time of day will flash on and off which indicates the time of day should be reset. Then the softener flushes the salt brine out of the treatment medium and down the drain so the cleaned treatment medium will be ready to treat more water. 4 Unit not tested for capacity at these flow rates. The distance between the drain and the water conditioner should be as short as possible. For Immediate Regeneration: Press and hold regen until valve motor starts (typically 3 seconds).

The system is isolated from the water pressure in the plumbing system. Allow to run until steady, clear and without air. With the softener in the bypass mode (Fig. For Regeneration the same night: Press and release regen (notice that flashing "REGEN TODAY" appears).

Honda Odyssey Engine For Sale